Tel:0086-18957494956

E-mail:[meiliga kaitstud]

EN
kõik kategooriad

Avaleht>teenused>Müügijärgne hooldus

Müügijärgne hooldus


Service throughout the entire lifespan of your product
IF THE PROBLEM IS: AND THIS CONDITION EXISTS: THEN DO THIS:
Pilot won’t light Cylinder valve is closed Open valve
Blockage in orifice or pilot tube Clean or replace orifice or pilot tube#
Air in the gas line Open gas line and bleed it (pressing control knob in) for not more than 1-2 minutes or until you smell gas
Low gas pressure Gas cylinder low or empty
Igniter fails Use match to light pilot, and obtain new igniter and replace. ( See below pictures)
Pilot won’t stay lit Dirt build up around pilot Clean dirt from around pilot
Connection between gas valve and pilot assembly is loose Tighten connection and perform leak test
Bad thermopaar Vahetage termopaar välja
Burner won’t light Gas pressure is low Replace gas cylinder
Blockage in orifice Clear blockage
Control knob is not in "ON" position Turn control knob to "ON" position
Burner flame is low Gas pressure is low Replace gas cylinder
Note: Do not operate heater below 5(40°F) Outdoor temperature is greater than 5(40°F) and tank is less than 25% full Replace gas cylinder

Supply hose is bent or kinked Straighten hose and perform leak test on hose

Control knob is fully " ON" Turn control knob to "OFF", let it cool to room temperature and check burner and orifices for blockage
Emitter glows uneven Gas pressure is low Replace gas cylinder
Note: Bottom 2.5cm of emitter normally does not normally glow Base is not on a level surface Place heater on a level surface

Heater not level Level heater
Carbon build-up Dirt or film on reflector and emitter Clean reflector and emitter
Thick black smoke Blockage in burner Turn control knob to "OFF", let it cool to room temperature and remove blockage and clean burner inside and outside.